Catalina Series
3D dispensing laser traces the dispense path and measures surface variation, then adapts height of the dispense tip to maintain a consistent gap. Dispense pumps can be fed from either syringe or bulk reservoirs. Depending on the pump selected for the process, syringe sizes can vary from 3 cc to 55 cc. Larger cartridges, such as 20 ounces, can be mounted on the site of the robot and pressure fed to the pump. For high volume applications that require the transfer of fluid from large reservoirs, the necessary ram or pump can be interfaced with the Catalina Series.
- Easy interfacing with a variety of dispense pumps
- Easy, manual loading and unloading of product
- 3D Dispensing which traces the dispense path and measures surface variation
- Small footprint
- Image Alignment points to account for product rotation
- Easy duplicate matrix dot dispensing
- Range of Operation (X, Y): 300 mm x 300 mm (11.8" x 11.8")
- Range of Operation (Z): 150 mm (5.9")
- Speed (X, Y): 600 mm/sec (24"/sec)
- Speed (Z): 500 mm/sec (20"/sec)
- Repeatability (X, Y, Z): ±0.02 mm (±0.0008")
- Accuracy ±0.035 mm (±0.0014")
- Dimensions (W x D x H) 60 cm x 70 cm x 75 cm (23.4" x 27.5" x 29.5")